国产精品国产三级在线专区,亚洲午夜国内自产拍在线观看,在线观看国产视频一区,善良的嫂子中文字幕在线

歡迎進(jìn)入濟南濟柴環(huán)能燃?xì)獍l(fā)電設(shè)備有限公司官網(wǎng)!
當(dāng)前位置:首頁 - 新聞中心 - 公司新聞

公司新聞

沼氣發(fā)電機組耗氣量高的檢查方式

返回 2023.01.03 來源:http://www.pp198.cn 0
沼氣發(fā)電機組經(jīng)過一段時間使用后,出現(xiàn)耗氣量過高的現(xiàn)象,這時要檢查沼氣發(fā)電機組狀況,如下:
After using the biogas generator set for a period of time, the gas consumption is too high. At this time, check the condition of the biogas generator set, as follows:
1)檢查沼氣發(fā)電機組水溫是否低于80℃,使減壓器加熱不良,或減壓器循環(huán)水管被堵,造成減壓器有結(jié)冰,混合氣偏濃。
1) Check whether the water temperature of the biogas generator set is lower than 80 ℃, which causes poor heating of the pressure reducer, or the circulating water pipe of the pressure reducer is blocked, which causes the pressure reducer to freeze and the mixture gas is too thick.
2)高低壓沼氣管線、混合器與節(jié)氣門連接處、進(jìn)氣管、沼氣裝置及鋼瓶是否漏氣。
2) Whether the high and low pressure biogas pipeline, the connection between the mixer and the throttle valve, the intake pipe, the biogas device and the steel cylinder leak.
3)空氣濾清器是否干凈,進(jìn)氣管路是否暢通。
3) Check whether the air filter is clean and whether the air inlet pipe is unblocked.
4)混合器流量是否調(diào)整不當(dāng),使混合氣過濃。在保證正常啟動的情況下,再在混合器膜片上加0.1mm厚銅墊或適當(dāng)關(guān)小功率閥。
4) Whether the flow of the mixer is adjusted improperly to make the mixture too rich. Under the condition of ensuring normal startup, add 0.1mm thick copper pad on the mixer diaphragm or turn down the power valve properly.
沼氣發(fā)電機組
5)中冷增壓沼氣發(fā)電機組減壓器出口壓力高,高可達(dá)80Kpa,使用檢漏液檢查沼氣出口到進(jìn)氣管之間各部件是否有漏氣,用壓縮空氣檢查。
5) The outlet pressure of the pressure reducer of the intercooled booster biogas generator set is high, up to 80Kpa. Use the leak detection solution to check whether there is gas leakage in the components between the biogas outlet and the intake pipe, and use compressed air to check.
6)低壓減壓器輸出壓力是否過高。
6) Whether the output pressure of low pressure reducer is too high.
7)檢查蓄電池電壓是否過低和點火系統(tǒng)是否有故障。
7) Check whether the battery voltage is too low and whether the ignition system is faulty.
8)斷缸法檢查各缸工作情況。
8) Check the working condition of each cylinder with the cylinder cut-off method.
9)所有沼氣發(fā)電機組動力不足,均會引起耗氣量增加。
9) Inadequate power of all biogas generator units will lead to increased gas consumption.
上述檢查完成后,若仍沒有解決沼氣耗氣量高的問題,則可能是沼氣發(fā)電機組技術(shù)狀況下降,需要檢查氣門間隙,各缸的氣缸壓力。更多相關(guān)內(nèi)容就來我們網(wǎng)站http://www.pp198.cn進(jìn)行咨詢吧!
After the above inspections are completed, if the problem of high biogas consumption is still not solved, it may be that the technical condition of the biogas generator set has declined, and the valve clearance and cylinder pressure of each cylinder need to be checked. More relevant content will come to our website http://www.pp198.cn Consult!
新聞搜索
濟南濟柴環(huán)能燃?xì)獍l(fā)電設(shè)備有限公司
  • 服務(wù)熱線

    0531-62325028
    0531-69951266

沼氣發(fā)電機組耗氣量高的檢查方式

沼氣發(fā)電機組經(jīng)過一段時間使用后,出現(xiàn)耗氣量過高的現(xiàn)象,這時要檢查沼氣發(fā)電機組狀況,如下:
After using the biogas generator set for a period of time, the gas consumption is too high. At this time, check the condition of the biogas generator set, as follows:
1)檢查沼氣發(fā)電機組水溫是否低于80℃,使減壓器加熱不良,或減壓器循環(huán)水管被堵,造成減壓器有結(jié)冰,混合氣偏濃。
1) Check whether the water temperature of the biogas generator set is lower than 80 ℃, which causes poor heating of the pressure reducer, or the circulating water pipe of the pressure reducer is blocked, which causes the pressure reducer to freeze and the mixture gas is too thick.
2)高低壓沼氣管線、混合器與節(jié)氣門連接處、進(jìn)氣管、沼氣裝置及鋼瓶是否漏氣。
2) Whether the high and low pressure biogas pipeline, the connection between the mixer and the throttle valve, the intake pipe, the biogas device and the steel cylinder leak.
3)空氣濾清器是否干凈,進(jìn)氣管路是否暢通。
3) Check whether the air filter is clean and whether the air inlet pipe is unblocked.
4)混合器流量是否調(diào)整不當(dāng),使混合氣過濃。在保證正常啟動的情況下,再在混合器膜片上加0.1mm厚銅墊或適當(dāng)關(guān)小功率閥。
4) Whether the flow of the mixer is adjusted improperly to make the mixture too rich. Under the condition of ensuring normal startup, add 0.1mm thick copper pad on the mixer diaphragm or turn down the power valve properly.
沼氣發(fā)電機組
5)中冷增壓沼氣發(fā)電機組減壓器出口壓力高,高可達(dá)80Kpa,使用檢漏液檢查沼氣出口到進(jìn)氣管之間各部件是否有漏氣,用壓縮空氣檢查。
5) The outlet pressure of the pressure reducer of the intercooled booster biogas generator set is high, up to 80Kpa. Use the leak detection solution to check whether there is gas leakage in the components between the biogas outlet and the intake pipe, and use compressed air to check.
6)低壓減壓器輸出壓力是否過高。
6) Whether the output pressure of low pressure reducer is too high.
7)檢查蓄電池電壓是否過低和點火系統(tǒng)是否有故障。
7) Check whether the battery voltage is too low and whether the ignition system is faulty.
8)斷缸法檢查各缸工作情況。
8) Check the working condition of each cylinder with the cylinder cut-off method.
9)所有沼氣發(fā)電機組動力不足,均會引起耗氣量增加。
9) Inadequate power of all biogas generator units will lead to increased gas consumption.
上述檢查完成后,若仍沒有解決沼氣耗氣量高的問題,則可能是沼氣發(fā)電機組技術(shù)狀況下降,需要檢查氣門間隙,各缸的氣缸壓力。更多相關(guān)內(nèi)容就來我們網(wǎng)站http://www.pp198.cn進(jìn)行咨詢吧!
After the above inspections are completed, if the problem of high biogas consumption is still not solved, it may be that the technical condition of the biogas generator set has declined, and the valve clearance and cylinder pressure of each cylinder need to be checked. More relevant content will come to our website http://www.pp198.cn Consult!
平顺县| 玉门市| 尚志市| 东明县| 来安县| 邯郸县| 黔江区| 高唐县| 兰西县| 成武县| 永丰县| 石林| 云浮市| 扶风县| 罗山县| 琼海市| 宜章县| 吉安县| 镇巴县| 长武县| 昌江| 读书| 巍山| 浠水县| 宣城市| 罗江县| 兰西县| 台北市| 临颍县| 广河县| 沾益县| 晋中市| 通河县| 东乌| 嘉禾县| 清镇市| 长武县| 城固县| 射阳县| 靖西县| 浦东新区|